Aube (a Honeywell Company) Programmable Heat Only Thermostat for Floor Heat - 120V / Double-Pole- 4 Wires. This thermostat has two modes of operation. Floor Mode - controls and displays the floor temperature using an external temperature sensor (included). AF Mode - controls and displays the ambient air temperature and maintains floor temperature within desired limits using external temperature sensor (included).
Features:
- Electronic precision temperature control.
- 7 day programmable - maintain the pre-set program schedule for up to 20% energy savings, or modify the schedule to fit your lifestyle.
- "Early Start" mode can be used to calculate optimal time to start heating in order to obtain the desired temperature by the set time.
- Large, clear, backlit display - easy to read in various lighting conditions.
- Soundproofed for quiet operation - reduces the clicking noise commonly heard with conventional thermostats.
- Heating indicator - at a glance confirmation that the heat is on.
- On/Standby switch allows you to turn the thermostat off at the end of the heating season.
- Includes Built-In GFCI
- Includes floor sensor with 15 foot cord
- Maintenance free - no batteries required.
- 3-year limited warranty.
Specifications:
Description Line Volt Electric Heating (Ambient and Floor) Manual Thermostat with 15 mA Class A EGFPD
Application Radiant floor
Mounting Vertical
Color White
Power Method Hardwired
Electrical Connections 6 in. (150 mm) tinned copper lead wires
Switch Positions (System) °C/°F
Switch Positions (System) AF (ambient+floor)/ F (floor only)
Switch Type Epoxy-soundproofed relay
Switching Action DPST
Accuracy (F) 0.9 F
Dimensions (in.) 4.9 in X 2.8 in X 0.9 in
Setting Temperature Range (F) 40 F to 86 F ambient
Setting Temperature Range (F) 40 F to 104 F floor
Differential Temperature (F) 1 F
Electrical Ratings Max. 1800 W @ 120 VAC, 15 A
Frequency 50 Hz
Frequency 60 Hz
Cycles per Hour 4
Sensor Element Thermistor
LEDs On EGFPD test button
Minimum Temperature Setting (F) 40 F (floor & ambient)
Maximum Temperature Setting (F) 86 F ambient
Maximum Temperature Setting (F) 104 F floor
Ambient Temperature Range (F) AF mode: 32 F to 122 F
Ambient Temperature Range (F) F mode: 32 F to 140 F
Approvals, Canadian Standards Association Approved
Includes Aube AC112-01 North American Sensor, 15 feet (4.6 m) or 50 feet (15 m)
Voltage 120 Vac