White-Rodgers 1F80-361 (1F80-261) Programmable (5+1+1 day) 1 Heat/1 Cool Thermostat


click to zoom

Product
Our#:101146
Mfg:White-Rodgers
Mfg#:1F80-361
Availability
NO LONGER AVAILABLE - Replaced by 1F80-0261
Shipping
Zip:
Replaces 1F80-261 and 1F80-51.

NOTE:  No Longer Available - Replaced by model 1F80-0261

FEATURES
• Battery powered or hardwired.
• Fossil fuel or electric heat compatible.
• 60% larger LCD with backlight.
• Permanent program retention during power loss.
• Configuration menu allows keypad selection of options.
• Selectable Celsius or Fahrenheit temperature display.
• Selectable Energy Management Recovery
• Meets Energy Star specifications
• Classic White color.

SPECIFICATIONS
Electrical Rating:
Dual Power or Battery Power Model . . . . mV to 30 VAC, NEC Class II, 50/60 Hz or DC
Input-Hardwire Model . . . . . . . . . . . . . . . . 20 to 30 VAC
Terminal Load . . . . . . . . . . . . . . . . . . . . . . . 1.0 A per terminal,
1.5A maximum all terminals combined
Setpoint Temperature Range . . . . . . . . . . . 45 to 90°F (7 to 32°C)
Anticipation, Heating . . . . . . . . . . . . . . . . . . Adjustable
Anticipation, Cooling . . . . . . . . . . . . . . . . . . Fixed
Rated Differential, Heat . . . . . . . . . . . . . . . 0.6° or 1.5°F
Rated Differential, Cool . . . . . . . . . . . . . . . . 1.2°F
Operating Ambient Temperature Range . . . 32 to 105°F (0 to 44°C)
Operating Humidity Range . . . . . . . . . . . . . 0-90% RH noncondensing
Shipping Temperature Range . . . . . . . . . . . -4 to +149°F (-20 to +65°C)
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . 33/4”H x 6”W x 11/4”D