|
|
|
|
|||||||||||||||||
|
The Inductor In-Line Duct Fan solves air delivery problems without major system rework or expense. Double crimped for easy flex duct installation. NEVER expose your Inductor® to airflow temperatures exceeding 140°F (60°C). · Make sure all electrical wiring conforms to all applicable codes and standards. If you are not familiar with electrical installations, consult a qualified electrician. FAQs Your problem room may be located far from the furnace. Friction in the long duct reduces airflow to the register in that room, thus delivery of heated air. Also, perhaps the room is over an unheated garage or the duct is simply too small (undersized) to get enough heated air to that room. Remember too, when you are delivering heated air to a room, that air has to have a way to get out of that room. Otherwise there will be no air circulation. Does the room have an air return register? If not, is the door of that room kept closed, stopping air circulation? Why do I have a room that is always too hot? The room that you have a cooling problem with may be far away from the central air system. Long duct runs cause reduction in airflow, plus, the cooled air may have heated up before it gets to the problem room. Perhaps the problem run is to a room on the South side of the house, which has a large window, catching a lot of summer heat. What boost can I expect from an Inductor? A standard floor or wall register is normally fed by a 6" diameter duct. You would like to boost the airflow from that register because you have a room that is usually cold in the winter or hot in the summer. What temperature difference does boosted airflow make? This is dependent on a host of variables. How well insulated is the room? What heat gain in the summer through a window? How far is the register from the furnace? Is this room over an unheated garage? Etc. How much power does an Inductor use? Example: The DB206, 6" diameter Inductor is rated at 0.35 Amp. What type of motors are used in Suncourt products? The electric motors used in Suncourt products are C-Frame two-pole motors, Class B, Thermally Protected, sleeve bearings and synthetic lubricant. The exceptions are the 400 Series Inductors which have 4-pole, Class B, Thermally Protected motors with sleeve bearings and synthetic lubricant. Can I use a rheostat or fan speed control with an Inductor? No. A rheostat lowers the voltage supplied to the fan motor. This will cause the motor to overheat and the Thermal Protector will open, destroying the motor. What does Thermally Protected mean? A thermally Protected motor contains a fuse that will cut off power to the motor should the motor temperature exceed a safe limit. All Suncourt electric motors are Thermally Protected. What are the fan blades made of? Our smaller Inductors are equipped with Polycarbonate fan blades. (A high strength superior material as used for jet fighter canopies). All others have aluminum fan blades. Exception: The fan blade of models DB102, DB205 and DB305 are made of a flame retardant Valox material. How many Inductor fans can I install? We recommend that you do not install more than 2 Inductors per 8 registers in your air distribution system. Will an Inductor always double airflow from any register? No. An Inductor will boost airflow more to a poorly performing register (which is the register needing help) than to a register that already has good airflow. As stated before, a poorly performing register may have double the airflow with an Inductor. A well performing register may have a 30% to 50% percent increase in airflow. What is the difference between Free Air and Boosted Air? Free air is the air volume output from a fan, expressed in Cubic Feet per Minute (CFM) when the fan is not connected to any ductwork, pipes, louvers or other items that would interfere with the free flow of air from the fan. Can I "over boost" a register? Suncourt Inductors are designed to provide progressive boost. This means that the airflow is proportionally boosted to the need of a particular register. Our booster fans are designed to run at a low RPM in free air. At this RPM, the fan motor runs below the peak torque that can be generated by the motor. Depending on the air blown into the intake side of the Inductor, the RPM will adjust itself as needed to provide boost and will operate at or near peak torque of the electric motor. In what type of duct can I install an Inductor? Inductors are suitable for installation in metal, flexible or high density pressed fiberglass ducts. The Inductor can be secured to the duct with screws or a good quality duct tape. Can I build-in an Inductor, i.e. drywall or panel over it? No. The Inductor must always remain accessible for service, cleaning or repair. Can I use the Inductor to vent outside air? The Inductor has to be protected from rain and excessive moisture. What is the lowest airflow temperature for an Inductor? To maintain good oiling of the motor bearings, we recommend a minimum temperature of 40°F (4°C). What do I typically need for electrical installation? You will need a small electrical box to mount on the Inductor. Where do I get power from for the Inductor? Here you have a number of options. Because of the numerous variations in furnace wiring, Suncourt cannot advise you on the hookup. Can I wire my two-speed Inductor to run on High or Low speed? Yes, but first this warning. NEVER connect the High and Low speed wires together. My Inductor seems to have a vibration. When handling and installing your Inductor, make sure not to touch the Aluminum fan blade. If you accidentally bend one or more of the vanes of the fan blade, you will get a vibration. Spin the fan blade carefully by hand and check that all vanes are the same distance from front-to-back. Please also visit the NOISE page in this section. There is no risk of bending the Polycarbonate or Valox blades used in some models. Is the Inductor safe? The Inductors have been rigorously tested to the Standards of Underwiters Laboratories Inc. and proudly display the Listing symbols of both Underwriters Laboratories Inc. (UL®) and Intertech Testing Services Ltd. (ETL®). All Inductors have Thermally Protected electric motors. |
|



