You Are Here: Home > Products > Thermostats & Controls > Thermostats > Specialty Thermostats > Attic Thermostats > Panasonic Whisper Control Humidity Sensing Fan Switch - Light Almond
Panasonic Whisper Control Humidity Sensing Fan Switch - Light Almond


click to zoom
(2 more images)

Product
Our#:176969
Mfg:Panasonic
Mfg#:FV-WCCS1-A
Availability
In Stock
Price: $46.08
Quantity:
Shipping
Standard: 2-7 Business Days: Free!

Zip:
* Prices reflect shipping fees for a quantity of (1)

Panasonic Whisper Control Humidity Sensing Fan Switch - FV-WCCS1-A (Light Almond)

This innovative switch is intended for use in problem areas of a home, such as near the shower or bath. If condensation is a problem or is suspected to be a problem, simply replace your existing fan switch with the WhisperControl fan switch.

Features:

  • Fan turns off when condensation is no longer present on the walls
  • Saves energy
  • Low maintenance
  • Long product life
  • Use with your existing fan
  • Manual on/off control also included
  • Wallplate included - but switch can be used with other switches in multi-ganged junction box
  • Max Fan Load - 3 Amp

For the switch to sense dew (condensation), the room will need to show visible signs of wetness attaching to surfaces, such as steam on walls / mirrors / fixtures. Visible steam in the air is not the problem, the problem occurs when moisture in the air becomes too heavy and the air cannot support the moisture. The moisture then moves to surfaces (this is the dew point), triggering the switch sensors. The remarkable Whisper Control fan switch is constantly checking the air for condensation. At the right time the switch will turn ON your fan and run the fan to clear the room.

Advantages of Whisper Control over standard dehumidistats and humidity sensors:

  • This control measures and anticipates the need to expel humid air based on dew point. The sensor is programmed to function in all seasons for all Climate Zones. The sensor humidity detection function is based on the psychrometric chart for dew point which makes this control much more accurate and reliable. The delay from sensing dew point and turning on the fan is 5 seconds which will meet your expectations to have the mirror cleared of condensation while showering.
  • Standard humidity sensors can be +/- 8% Relative Humidity or higher. They are based on rapid rise in humidity which varies by season and Climate Zone. Standard humidity sensors are not as accurate so it is possible to have exhaust fans run either too little or too much.

Maximum Fan Load: 1/8th hp or 3 amps

Operation and Testing:
Press the upper button to see the fan turn ON, press the lower button to see the fan turn OFF.
With the fan off, you can test the sensor by blowing into the sensor as if you were blowing on a mirror to steam it.  After blowing on the sensor with two or three puffs of breath, wait 10 seconds and the fan will come ON automatically.  You will see the blue LED pulse slowly at the rate of one pulse every four seconds.  This shows you the control is sensing condensation.  You can manually turn OFF the fan or allow the 30 minute timer to run.
You can override the sensor to make the control and manual switch only.  Press both the ON and OFF buttons simultaneously and hold them down for 20 seconds.  To reactivate the sensor and LED features, press and hold down both ON and OFF again for 20 seconds.  Now the control is once again sensing for condensation.
NOTE: When the fan has been turned ON by the manual button or the presence of condensation - the control will turn itself back to OFF after 30 minutes.  If the controls senses condensation the blue LED will pulse very slowly once every four seconds.  At all times, you can manually turn OFF or ON the fan just a you would with a common switch.