You Are Here: Home > Products > Thermostats & Controls > Thermostats > Multi-Stage Heat/Cool > Braeburn Model 5200 2 Heat/2 Cool Programmable Multistage Thermostat
Braeburn Model 5200 2 Heat/2 Cool Programmable Multistage Thermostat


click to zoom
(4 more images)

Product
Our#:172303
Mfg:Braeburn
Mfg#:5200
Availability
NO LONGER AVAILABLE
Shipping
Standard: 2-7 Business Days: Free!

Zip:
* Prices reflect shipping fees for a quantity of (1)

Braeburn Model 5200 2 Heat/2 Cool Programmable Multistage Thermostat  - REPLACED BY MODEL 5220

The digital programmable thermostat shall be a BraeburnŽ, model number 5200, 4.63" high x 5.00" wide x 1.25" deep, powered by 24 Volt AC with two "AA" Alkaline batteries (3.0 Volt DC) to retain clock settings and universal 7 or 5-2 day switch selectable programming. The thermostat shall be compatible with multi-stage heat pump systems with up to two stages of heating and two stages of cooling. The thermostat shall have a bright blue backlight display, front loading battery door, separate sub-base for trouble free installation and keypad lockout. Temperature control range shall be between 45° and 90° F (7° and 32° C), accuracy of +/- 1° F (+/- .5° C), humidity range between 5% and 95% relative humidity. The thermostat shall include non-volatile memory to retain user settings, filter check monitor, adaptive recovery mode (ARMT), separate heating and cooling set point program times and temperatures, programmable recirculating fan mode, residual cooling fan delay, auxiliary heat fossil fuel switch, multi-colored LED status indicators and compressor power outage protection. A front reset button will return user settings to default values when pressed. The thermostat can be mounted to a horizontal or vertical junction box.

FEATURES:

. Universal 7 Day or 5-2 Day Programming
. Large Display with Bright Blue Backlight
. AC Powered with Battery Back-Up
. Non-Volatile Memory to Maintain User Settings
. Recirculating Fan Mode
. Residual Cooling Fan Delay
. Filter Check Monitor
. Adaptive Recovery Mode (ARMT)
. Adjustable 1st and 2nd Stage Temperature Differential
. Auxiliary Heat Fossil Fuel Switch
. ESD GuardT Electronic Circuitry
. Compressor Short Cycle Protection
. Compressor Power Outage Protection
. AC Power Monitor
. Separate Heating and Cooling Set Point Program Times and Temperatures
. Temporary Program Override for 4 Hours or Until Next Set Point
. Programmable Extended Hold Mode
. Front Access Reset Button
. F° / C° Switch
. Gas / Electric Fan Switch
. Mounts to Vertical or Horizontal Box
. Easy Access Front Battery Door
. Separate O & B Terminals
. Multi-Colored LED Status Indicators
. Keypad Lockout
. Meets ENERGY STARŽ and California Title 24 Guidelines

SPECIFICATIONS:

Dimensions: 4.63" x 5.00" x 1.25"
Electric Rating: 24 Volt AC (18-30 Volt AC)
1 amp maximum load per terminal
3 amp total maximum load (all terminals)
AC Power: 18-30 Volt AC
DC Back-Up Power: 3.0 Volts DC
(2 "AA" Alkaline batteries included)
Compatibility: Multi-stage heat pump systems with up to two stages of heating and two stages of cooling
Control Range: 45° to 90° F (7° to 32° C)
Display Range: 40° to 99° F (4° to 37° C)
Accuracy: +/- 1° F (+/- .5° C)
Temperature Differential: 1st Stage - .5°, 1°, or 2° F (.25°, .5°, or 1° C)
2nd Stage - 2°, 3°, 4°, 5°, or 6° F
(1°, 1.5°, 2°, 2.5°, or 3° C)
Storage Temperature: 14° to 140° F (-10° to 60° C)
Operating Humidity: 5% to 95% Relative Humidity
Interchangeable Sub-Base: Braeburn 3200 Non-Programmable
2 Heat / 2 Cool Heat Pump
Terminations: R, Y1, Y2, W2, E, G, O, B, L, C