1.  Note manual humidifier control setting an turn dial to the "off" position.
2.  Disconnect electrical power, turn water supply off.
3.  Disconnect
a) 120 volt electrical service.
b) Copper Water Supply Line (1) and feed tube (2).
c) Drain line. d) 24 volt leads.
4.  Turn two swing locks (3), one at either side of the lower housing of humidifier flange 
5. Lift humidifier straight up until bottom of t humidifier clears lip of lower housing.  Pull humidifier out at bottom, lower and remove.
6.  Slide off three closure clips (4 & 5) that hold 2 halves of humidifier together.
7. Remove upper half of humidifier.  Remove water distribution pan cover (6) and remove any mineral deposits from the "V" notches.  DO NOT scrape off granular coating from the bottom.  This textured surface helps ensure even water flow for maximum performance.  If the granular coating has been removed.  place several drops of liquid dishwashing soap on the distribution tray.  This will only need to be done once if there is no granular coating.
8. Remove water panel evaporator and scale control insert
9. Remove water panel evaporator from insert and clean insert by flexing or using putty knife.  If scale control insert is not used., contact your dealer about obtaining one.
10. Install a new water panel evaporator with colored spot UP, in scale control insert.  IMPORTANT - when installing scale control insert and water panel evaporator into the humidifier, the insert spout must discharge directly into the drain.
11. Remove drain line (7) from the bottom of the humidifier.  If applicable, flex it to loosen any mineral deposits or blockages.  Then flush it with water under pressure.  If it does not properly clear, replace it.  Slip drain line back onto the drain fitting.  Make sure the drain line has a constant downward slope and is not flattened or blocked.
12.  Following water panel evaporator replacement and maintenance - reassemble humidifier.
13.  Reconnect electrical power
14. Turn on water supply
15. Check system operation: With the furnace blower operating, burn up manual humidifier control and check system operation.
16. Set manual humidifier control to it's original position.